EL3318 BECKHOFF PLC Programming Terminal

Model: EL3318 BECKHOFF PLC Programming Terminal

Technical data EL3318 Numb…

  • Genuine products, direct from the factory
  • Technical selection and commissioning support
  • Bulk purchasing and customization available

Specifications & Service

MOQ 1 PCS
Warranty 1 year
Delivery Time 3-5 days
Shipping FedEx/DHL/UPS/TNT
Payment TT/Western Union

Product Details

Technical data EL3318
Number of inputs 8
Power supply via the E-bus
Distributed clocks –
Input filter limit frequency typ. 1 kHz
Connection method 2-wire
Conversion time approx. 2.5 s up to 20 ms, depending on configuration and filter setting, default: approx. 250 ms
Voltage measurement ±30/±60/±75 mV
Resolution 16 bit, representation adjustable: 0.1/0.01°C or 1/2/4 µV per digit
Temperature measurement (thermocouple) type B, C, E, J, K, L, N, R, S, T, U (default setting: type K)
Measurement uncertainty (temperature measurement) at 23°C ambient temperature, with internal cold junction, according type: B: ±6.3°C; C: ±4.9°C; E: ±3.1°C; J: ±3.2°C; K: ±3.4°C; L: ±3.1°C; N: ±3.4°C; R: ±5.2°C; S: ±5.4°C; T: ±3.3°C; U: ±3.2°C; for further details see documentation
Measurement uncertainty (voltage measurement) at ±75 mV, 23°C ambient temperature: < ±0.096% (relative to full scale value)
Electrical isolation 500 V (E-bus/signal voltage)
Current consumption power contacts –
Current consumption E-bus typ. 210 mA
Special features channel by channel wire break detection, internal and external cold junction, firmware filter adjustable
Operating/storage temperature -25…+60°C/-40…+85°C
Weight approx. 70 g
Relative humidity 95%, no condensation
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Approvals/markings CE, UL, ATEX, IECEx, cFMus
Protect. rating/installation pos. IP20/variable
Ex marking ATEX:
II 3G Ex ec IIC T4 Gc
IECEx:
Ex ec IIC T4 Gc
cFMus:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2, AEx ec IIC T4 Gc
Housing data EL-12-16pin
Design form HD (High Density) housing with signal LEDs
Material polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Installation on 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means of double slot and key connection
Marking labeling of the BZxxx series
Wiring solid conductors (s): direct plug-in technique; fine-stranded conductors (st) and ferrule (f): spring actuation by screwdriver
Connection cross-section s*: 0.08…1.5 mm²,
st*: 0.25…1.5 mm²,
f*: 0.14…0.75 mm²
Connection cross-section AWG s*: AWG28…16,
st*: AWG22…16,
f*: AWG26…19
Stripping length 8…9 mm
Current load power contacts Imax: 10 A