S5735-L48T4X-A1 Huawei Switches

Model: S5735-L48T4X-A1 Huawei Switches

S5735-L48T4X-A1 Specificat…

  • Genuine products, direct from the factory
  • Technical selection and commissioning support
  • Bulk purchasing and customization available

Specifications & Service

MOQ 1 PCS
Warranty 1 year
Delivery Time 3-5 days
Shipping FedEx/DHL/UPS/TNT
Payment TT/Western Union

Product Details

S5735-L48T4X-A1 Specification

Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
Chassis height [U] 1 U
Typical power consumption [W] 43.2 W
Typical heat dissipation [BTU/hour] 147.4 BTU/hour
Maximum power consumption [W] 51.9 W
Maximum heat dissipation [BTU/hour] 177.09 BTU/hour
MTBF [year] 53.67 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 48 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 36.2 dB(A)
Number of card slots 0
Number of power slots 0
Number of fans modules 1
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Short-term operating temperature [°C(°F)] -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used.

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

  • The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.
  • The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode AC built-in
Rated input voltage [V] AC input: 100 V AC to 240 V AC, 50/60 Hz
Input voltage range [V] AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz
Maximum input current [A] 2 A