| Product Model |
3RW4027-1TB04 |
| Brand |
Siemens |
| Product Series |
SIRIUS |
| Product Type |
Soft Starter |
| Frame Size |
S0 |
| Operating Voltage Range |
200-480 V AC (standard circuit) |
| Control Supply Voltage |
24 V AC/DC (AC: ±15% tolerance; DC: ±20% tolerance) |
| Operating Frequency |
50-60 Hz (±10% tolerance) |
| Rated Operational Current (40°C) |
32 A |
| Operational Current (50°C) |
29 A |
| Operational Current (60°C) |
26 A |
| Rated Power (400V, 40°C, 3-phase) |
15 kW |
| Rated Power (230V, 40°C, 3-phase) |
7.5 kW |
| Rated Power (460/480V, 50°C, 3-phase) |
20 hp |
| Insulation Voltage |
600 V |
| Max Thyristor Blocking Voltage |
1600 V |
| Protection Rating |
IP20 (front, IEC 60529) |
| Dimensions (W×H×D) |
45 mm × 125 mm × 155 mm |
| Mounting Method |
Screw and snap-on mounting |
| Mounting Position |
With additional fan: ±90° rotatable/±22.5° tiltable; Without fan: ±10° rotatable/tiltable |
| Required Side-by-Side Spacing |
Upwards: 60 mm; Side: 15 mm; Downwards: 40 mm |
| Auxiliary Contacts |
2×NO, 1×CO, 0×NC (UL contact rating: B300/R300) |
| Key Features |
Integrated bypass contact system, motor overload protection, thermistor evaluation, external reset, adjustable current limitation |
| Min. Load Requirement |
20% |
| Max. Installation Altitude |
5000 m |
| Operating Ambient Temperature |
-25…+60 °C |
| Storage Ambient Temperature |
-40…+80 °C |
| Power Loss (40°C, operational current) |
10 W (typical) |
| Pollution Degree |
3 (acc. to IEC 60947-4-2) |
| Certifications |
CE, CCC, EAC, KC, IECEx, UL/CSA |
| Main Terminal Conductor Cross-Section |
Solid: 2×(1-2.5 mm²)/2×(2.5-6 mm²) (max. 1×10 mm²); Finely stranded (with core end): 2×(1-2.5 mm²)/2×(2.5-6 mm²) |