B&R
8V1090.001-2 B&R ACOPOS Servo Drive – 4 KW
Model: 8V1090.001-2 B&R ACOPOS Servo Drive – 4 KW
General information Note V…
- Genuine products, direct from the factory
- Technical selection and commissioning support
- Bulk purchasing and customization available
Specifications & Service
| MOQ | 1 PCS |
|---|---|
| Warranty | 1 year |
| Delivery Time | 3-5 days |
| Shipping | FedEx/DHL/UPS/TNT |
| Payment | TT/Western Union |
Product Details
General information
| Note | Variant with partially coated printed circuit boards |
| B&R ID code | 0xA09B |
| Slots for plug-in modules | 4 |
| Certifications | |
| CE | Yes |
| UKCA | Yes |
| Functional safety | Yes |
| UL | cULus E225616 Power conversion equipment |
| EAC | Yes |
| KC | Yes |
Mains connection
| Permissible network configurations | TT, TN |
| Mains input voltage | 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed load | Max. 10 kVA |
| Inrush current at 400 VAC | 7 A |
| Switch-on interval | >10 s |
| Integrated line filter per EN 61800-3, category C3 | Yes |
| Power dissipation at device nominal power without braking resistor | Approx. 200 W |
DC bus connection
| DC bus capacitance | 470 µF |
24 VDC power supply
| Input voltage | 24 VDC ±25% |
| Input capacitance | 8200 µF |
| Current consumption | Max. 2.5 A + Current for motor holding brake |
Motor connection
| Quantity | 1 |
| Continuous current | 8.8 Aeff |
| Reduction of continuous current depending on ambient temperature | |
| Mains input voltage: 400 VAC | |
| Switching frequency 5 kHz | No reduction |
| Switching frequency 10 kHz | 0.18 Aeff per °C (starting at 54°C) |
| Switching frequency 20 kHz | 0.18 Aeff per °C (starting at 30°C) |
| Mains input voltage: 480 VAC | |
| Switching frequency 5 kHz | No reduction |
| Switching frequency 10 kHz | 0.18 Aeff per °C (starting at 48°C) |
| Switching frequency 20 kHz | 0.18 Aeff per °C (starting at 18°C) |
| Reduction of continuous current depending on installation elevation | |
| Starting at 500 m above sea level | 0.88 Aeff per 1000 m |
| Peak current | 24 Aeff |
| Nominal switching frequency | 10 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. motor line length | 25 m |
| Protective measures | |
| Overload protection | Yes |
| Short-circuit and ground fault protection | Yes |
| Max. output frequency | 598 Hz |
| Terminal connection cross section | |
| Flexible and fine-stranded wires | |
| With wire end sleeves | 0.25 to 4 mm² |
| Approbation data | |
| UL/C-UL-US | 30 to 10 AWG |
| CSA | 28 to 10 AWG |
Motor holding brake connection
| Response threshold for open-circuit monitoring | Approx. 385 mA |
| Max. output current | 1 A |
| Max. number of switching cycles | Unlimited since implemented electronically |
Braking resistor
| Peak power output | 7 kW |
| Continuous power | 200 W |
Limit switch and reference inputs
| Quantity | 3 |
| Circuit | Sink |
| Electrical isolation | |
| Input – ACOPOS | Yes |
| Input – Input | No |
| Input voltage | |
| Nominal | 24 VDC |
| Maximum | 30 VDC |
| Switching threshold | |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | Approx. 4 mA |
| Switching delay | Max. 2.0 ms |
| Modulation compared to ground potential | Max. ±38 V |
Enable inputs
| Quantity | 1 |
| Circuit | Sink |
| Electrical isolation | |
| Input – ACOPOS | Yes |
| Input voltage | |
| Nominal | 24 VDC |
| Maximum | 30 VDC |
| Input current at nominal voltage | Approx. 30 mA |
| Switching threshold | |
| Low | <5 V |
| High | >15 V |
| Switching delay | |
| Enable 0 → 1, ready for PWM | Max. 100 µs |
| Enable 1 → 0, PWM off | Max. 2.0 ms |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | Not permitted |
Trigger inputs
| Quantity | 2 |
| Circuit | Sink |
| Electrical isolation | |
| Input – ACOPOS | Yes |
| Input – Input | No |
| Input voltage | |
| Nominal | 24 VDC |
| Maximum | 30 VDC |
| Switching threshold | |
| Low | <5 V |
| High | >15 V |
| Input current at nominal voltage | Approx. 10 mA |
| Switching delay | |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Modulation compared to ground potential | Max. ±38 V |
Electrical properties
| Discharge capacitance | 660 nF |
| Energy efficiency (IE classification) | |
| Power loss relative to continuous apparent power | IE2 (10,25) 1.6% IE2 (50,25) 1.6% IE2 (10,50) 1.8% IE2 (50,50) 1.9% IE2 (90,50) 2% IE2 (10,100) 2.2% IE2 (50,100) 2.5% IE2 (90,100) 2.9% |
| Nominal losses in standby mode | 16.8 W |
Operating conditions
| Permissible mounting orientations | |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Standing horizontally | No |
| Installation elevation above sea level | |
| Nominal | 0 to 500 m |
| Maximum | 2000 m |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | II |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature | |
| Operation | |
| Nominal | 5 to 40°C |
| Maximum | 55°C |
| Storage | -25 to 55°C |
| Transport | -25 to 70°C |
| Relative humidity | |
| Operation | 5 to 85% |
| Storage | 5 to 95% |
| Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions | |
| Width | 70.5 mm |
| Height | 375 mm |
| Depth | 235.5 mm |
| Weight | 4.4 kg |