B&R 8BVE0500HW00.000-1 ACOPOSmulti Expansion Module Specification Sheet

Model: B&R 8BVE0500HW00.000-1 ACOPOSmulti Expansion Module Specification Sheet

Data Category Specific Par…

  • Genuine products, direct from the factory
  • Technical selection and commissioning support
  • Bulk purchasing and customization available

Specifications & Service

MOQ 1 PCS
Warranty 1 year
Delivery Time 3-5 days
Shipping FedEx/DHL/UPS/TNT
Payment TT/Western Union

Product Details

Data Category Specific Parameters
Product Model 8BVE0500HW00.000-1
Brand B&R
Product Type ACOPOSmulti Expansion Module
Mounting Method Wall mounting
Key Function Distributes DC bus & 24 VDC power for ACOPOSmulti drive systems; connects ACOPOSremote/ACOPOSmotor
DC Bus Nominal Voltage 750 VDC
Max Continuous Power (50A fuse) 30 kW (40 A eff continuous current)
Continuous Power (20A fuse) 12 kW (16 A eff continuous current)
Continuous Power (10A fuse) 6 kW (8 A eff continuous current)
Peak Current (50A fuse) 100 A
24 VDC Supply Input 25 VDC ±1.6%
24 VDC Max Power Consumption 5 W
24 VDC Continuous Power (30A fuse) 600 W
24 VDC Continuous Power (12A fuse) 240 W
Dimensions (W×H×D) 53 mm × 317 mm × 263 mm (wall mounting)
Net Weight Approx. 3.1 kg
Protection Rating IP20 (EN 60529)
Operating Temperature Range 5…40°C (nominal); max 55°C (with power derating)
Storage/Transport Temperature -25…55°C (storage); -25…70°C (transport)
Relative Humidity 5…85% (operation); 5…95% (storage/transport, non-condensing)
Max Installation Altitude 4000 m (10% power reduction per 1000 m above 500 m)
Power Derating (Ambient >40°C) 1.25% per °Kelvin
Monitoring Features Thermal monitoring of fuse holders (LED indicators: OLDC/OL24/OLD/HLD/NLD); 2 alarm contacts (1 NC, 1 NO)
Fuse Requirements DC bus: 2×14×51 mm fuses (10/20/50A, ultra-fast); 24VDC: 1×10×38 mm fuses (12/30A, fast-acting)
Certifications CE, KC, UL/cULus (E225616, Power Conversion Equipment)
Permissible Mounting Orientations Vertical hanging, horizontal lying (standing horizontally not permitted)
Max Distance Between Modules 5 m (using shielded ACOPOSmulti 8BCA cables)
Terminal Cross Section DC bus: 0.5…16 mm² (flexible/fine wire with sleeves); 24VDC: 0.25…6 mm²
Pollution Degree 2 (non-conductive pollution, EN 61800-5-1)
Overvoltage Category III (EN 61800-5-1)
Power Dissipation (Continuous Power) 200 W