| Supply circuit type |
AC |
| [Us] rated supply voltage |
400 V three phase – 10…10 %)
230 V three phase – 10…10 %)
230 V single phase – 10…10 %) |
| Supply frequency |
50/60 Hz +/- 5 % |
| [Uc] control circuit voltage |
24 V DC – 20…25 %) |
| Power supply output current |
84 A |
| Bus voltage |
270…700 V |
| Maximum DC bus voltage |
860 V |
| Maximum cable capacity |
1.36 mF |
| Line Rated Current |
21 A single phase AC
42 A three phase AC |
| Peak current |
42 A single phase AC 1 s
84 A three phase AC 1 s |
| Nominal power |
22.1 kW 400 V three phase AC
26.6 kW 480 V three phase AC |
| Maximum power |
44.2 kW 400 V three phase AC
53.2 kW 480 V three phase AC |
| Holding time |
15 min |
| Braking resistance |
15 Ohm |
| Permanent braking power |
400 W |
| Maximum braking power |
46 kW |
| Output type |
2 relays volt-free contacts |
| Physical interface |
SERCOS III |
| Marking |
CE |
| Safety level |
Can reach SIL 2 EN 61508
Can reach PL d/category 3 EN/ISO 13849-1 |
| Overvoltage category |
III EN 61800-5-1 |
| Depth |
10.6 in (270 mm) |
| Width |
3.5 in (89.5 mm) |
| Height |
12.2 in (310 mm) |
| Net Weight |
13.9 lb(US) (6.3 kg) |