RM35JA32MW Schneider Control relays

Model: RM35JA32MW Schneider Control relays

Main Range of Product Harm…

  • Genuine products, direct from the factory
  • Technical selection and commissioning support
  • Bulk purchasing and customization available

Specifications & Service

MOQ 1 PCS
Warranty 1 year
Delivery Time 3-5 days
Shipping FedEx/DHL/UPS/TNT
Payment TT/Western Union

Product Details

Main
Range of Product Harmony Control Relays
Relay Type Current control relay
Product or Component Type Current control relay
Relay name RM35JA
Relay monitored parameters Overcurrent or undercurrent detection
time delay Adjustable 0.3…30 s, 0 + 10 % Tt- time delay upon fault
Adjustable 1…20 s, 0 + 10 % Ti- inhibition time delay upon startup
Switching capacity in VA 1250 VA
Minimum switching current 10 mA 5 V DC
Maximum switching current 5 A AC/DC
Maximum power consumption in VA 3.5 VA AC
Measurement range 150 mA…15 A current AC/DC
Utilisation category AC-12 IEC 60947-5-1
AC-13 IEC 60947-5-1
AC-14 IEC 60947-5-1
AC-15 IEC 60947-5-1
DC-12 IEC 60947-5-1
DC-13 IEC 60947-5-1
DC-14 IEC 60947-5-1
Contacts type and composition 2 C/O
Complementary
Reset time 1500 ms time delay
Maximum switching voltage 250 V AC/DC
Supply voltage limits 20.4…264 V AC/DC
operating voltage tolerance – 15 % + 10 % Un
Maximum power consumption in W 0.6 W DC
Control circuit frequency 40…70 Hz +/- 10 %
Resistance across terminals 0.005 Ohm E3-M terminals
0.015 Ohm E2-M terminals
0.05 Ohm E1-M terminals
Output contacts 2 C/O
Nominal output current 5 A
Maximum measuring cycle 30 ms measurement cycle as true rms value
Hysteresis 5…50 % threshold setting
delay at power up 0.3 s
Measurement accuracy +/- 10 % of the full scale value
Repeat accuracy +/- 0.5 % input and measurement circuit
+/- 2 % time delay
Measurement error 0.05 %/°C with temperature variation
1 by volt over the whole range with voltage variation
Polarity No DC
Threshold setting 10…100 %
Marking CE : EMC 89/336/EEC
CE : 73/23/EEC
Overvoltage category III IEC 60664-1
Insulation resistance > 500 MOhm 500 V DC between supply and relay output IEC 60255-5
> 500 MOhm 500 V DC between measurement and relay output IEC 60664-1
> 1 MOhm 500 V DC between supply and measurement IEC 60255-5
> 500 MOhm 500 V DC between supply and relay output IEC 60664-1
> 500 MOhm 500 V DC between measurement and relay output IEC 60255-5
> 1 MOhm 500 V DC between supply and measurement IEC 60664-1
[Ui] rated insulation voltage 250 V IEC 60664-1
Operating position Any position without derating
Connections – terminals Screw terminals, 1 x 0.5…1 x 4 mm² AWG 20…AWG 11) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² AWG 20…AWG 14) solid without cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 24…AWG 12) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) flexible with cable end
Tightening torque 5.3…8.9 lbf.in (0.6…1 N.m) IEC 60947-1
Housing material Self-extinguishing plastic
Local signalling for power ON LED (green)
for relay ON LED (yellow)
Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Operating rate <= 360 operations/hour full load
[Un] rated nominal voltage 24…240 V AC/DC 50/60 Hz, non self-powered
Safety reliability data MTTFd = 296.8 years
B10d = 270000
Contacts material Cadmium free
Width 1.4 in (35 mm)
Control Type Without test button
Net Weight 0.29 lb(US) (0.13 kg)
Environment
Immunity to microbreaks 50 ms
Electromagnetic compatibility Emission standard for industrial environments conforming to IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Standards IEC 60255-6
Product Certifications GL
UL
GOST
C-tick
CSA
Ambient Air Temperature for Storage -40…158 °F (-40…70 °C)
Ambient air temperature for operation -4…122 °F (-20…50 °C)
Relative humidity 95 % 131 °F (55 °C) IEC 60068-2-30
Vibration resistance 0.35 mm 5…57.6 Hz)IEC 60068-2-6
1 gn 57.6…150 Hz)IEC 60255-21-1
Shock resistance 15 gn 11 ms IEC 60255-21-1
IP degree of protection IP20 IEC 60529 terminals)
IP30 IEC 60529 casing)
Pollution degree 3 IEC 60664-1
Dielectric test voltage 2 kV AC 50 Hz, 1 min IEC 60255-5
2 kV AC 50 Hz, 1 min IEC 60664-1
Non-dissipating shock wave 4 kV IEC 60255-5
4 kV IEC 60664-1
4 kV IEC 61000-4-5
Ordering and shipping details
Category US10CP222380
Discount Schedule 0CP2
GTIN 3389119405225
Returnability Yes
Country of origin CA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.772 in (4.500 cm)
Package 1 Width 3.150 in (8.000 cm)
Package 1 Length 3.740 in (9.500 cm)
Package 1 Weight 4.797 oz (136.000 g)
Unit Type of Package 2 S03
Number of Units in Package 2 48
Package 2 Height 11.811 in (30.000 cm)
Package 2 Width 11.811 in (30.000 cm)
Package 2 Length 15.748 in (40.000 cm)
Package 2 Weight 16.074 lb(US) (7.291 kg)