SR2B201JD Schneider Telemecanique

Model: SR2B201JD Schneider Telemecanique

Ambient Air Temperature Fo…

  • Genuine products, direct from the factory
  • Technical selection and commissioning support
  • Bulk purchasing and customization available

Specifications & Service

MOQ 1 PCS
Warranty 1 year
Delivery Time 3-5 days
Shipping FedEx/DHL/UPS/TNT
Payment TT/Western Union

Product Details

Ambient Air Temperature For Operation      : -20-40 deg. C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 deg. C IEC 60068-2-1 and IEC 60068-2-2
Ambient Air Temperature For Storage      : -40-70 deg. C
Analogue Input Number      : 6
Analogue Input Range      : 0…10 V || 0…12 V
Analogue Input Resolution      : 8 bits at maximum voltage
Analogue Input Type      : common mode
Backup Time      : 10 years 25 deg. C
California Proposition 65      : WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Checks      : program memory on each power up
China Rohs Regulation      : X
Circularity Profile      : ENVEOLI0604006EN
Clock Drift      : 12 min/year 0-55 deg. C || 6 s/month 25-25 deg. C
Clock      : with
Connections – Terminals      : screw terminals, 1 x 0.2…1 x 2.5 mm squared AWG 25…AWG 14) semi-solid || screw terminals, 1 x 0.2…1 x 2.5 mm squared AWG 25…AWG 14) solid || screw terminals, 1 x 0.25…1 x 2.5 mm squared AWG 24…AWG 14) flexible with cable end || screw terminals, 2 x 0.2…2 x 1.5 mm squared AWG 24…AWG 16) solid || screw terminals, 2 x 0.25…2 x 0.75 mm squared AWG 24…AWG 18) flexible with cable end
Contacts Type And Composition      : NO relay output
Conversion Error      : +/- 5 % 25 deg. C analogue input circuit || +/- 6.2 % 55 deg. C analogue input circuit
Conversion Time      : smart relay cycle time analogue input circuit
Counting Frequency      : 1 kHz discrete input
Current State 0 Guaranteed      : <= 0.9 mA I1…IA and IH…IR discrete input circuit) || <= 0.9 mA IB…IG used as discrete input circuit)
Current State 1 Guaranteed      : >= 2 mA I1…IA and IH…IR discrete input circuit) || >= 0.5 mA IB…IG used as discrete input circuit)
Cycle Time      : 6-90 ms
Discrete Input Current      : 4 mA
Discrete Input Number      : 12 EN/IEC 61131-2 type 1
Discrete Input Type      : resistive
Discrete Input Voltage      : 12 V DC
Disturbance Radiated/Conducted      : class B EN 55022-11 group 1
Electrical Durability      : AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1
Environmental Characteristic      : EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Environmental Disclosure      : ENVPEP060406EN
Eu Rohs Directive      : Pro-active compliance (Product out of EU RoHS legal scope)
Immunity To Microbreaks      : 10 ms repeated 20 times
Input Compatibility      : 3-wire proximity sensors PNP discrete input
Input Impedance      : 14 kOhm IB…IG used as analogue input circuit || 14 kOhm IB…IG used as discrete input circuit || 2.7 kOhm I1…IA and IH…IR discrete input circuit
Ip Degree Of Protection      : IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Local Display      : with
Lsb Value      : 39 mV analogue input circuit
Maximum Altitude Transport      : 3048 m
Maximum Permissible Voltage      : 14.4 V analogue input circuit
Maximum Supply Current      : 200 mA without extension)
Mechanical Durability      : 10000000 cycles relay output
Mercury Free      : Yes
Net Weight      : 0.38 kg
Number Of Outputs      : 8 relay
Number Or Control Scheme Lines      : 0-240 ladder || 0-500 FBD
Operating Altitude      : 6561.68 ft (2000 m)
Operating Distance      : 10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Operating Rate In Hz      : 0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Output Thermal Current      : 8 A for all 8 outputs relay output
Output Voltage Limits      : 24…250 V AC relay output) || 5…30 V DC relay output)
Overvoltage Category      : III EN/IEC 60664-1
Pollution Degree      : 2 EN/IEC 61131-2
Power Dissipation In W      : 2.5 W without extension
Product Certifications      : C-tick || GL || UL || CSA || GOST
Product Or Component Type      : compact smart relay
Pvc Free      : Yes
Range Of Product      : Zelio Logic
Rated Impulse Withstand Voltage      : 4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Rated Supply Voltage      : 12 V DC
Reach Regulation      : Reference contains Substances of Very High Concern above the threshold
Relative Humidity      : 95-95 % without condensation or dripping water
Repeat Accuracy      : +/- 2 % 55 deg. C analogue input circuit
Response Time      : 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Reverse Polarity Protection      : with
Rohs Exemption Information      : Yes
Standards      : EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-11 || EN/IEC 61000-4-5 || EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-12 || EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-3
Supply Voltage Limits      : 10.4-14.4 V
Sustainable Offer Status      : Green Premium product
Switching Capacity In Ma      : >= 10 mA 12 V relay output)
Tightening Torque      : 0.5 N.m
UPC – 11 Digit      : 33891105497
UPC – 12 Digit      : 338911054972
Voltage State 0 Guaranteed      : <= 3 V IB…IG used as discrete input circuit || <= 2.4 V I1…IA and IH…IR discrete input circuit
Voltage State 1 Guaranteed      : >= 7 V IB…IG used as discrete input circuit || >= 5.6 V I1…IA and IH…IR discrete input circuit